Tel : +86-592-6382791
Email : sales@pidmaxwell.com
The PIDMaxWell Type K & Type J Thermocouple Probes share an identical physical design, featuring a durable SS316 stainless steel, mineral-insulated sheath. The cable color distinguishes the type: Green for Type K (max 700°C) and Yellow for Type J (max 500°C). Both are equipped with a 2-meter silicone cable and a 10x40mm transition part. Ideal for high-temperature monitoring and PID controller applications.
Brand:
PIDMaxWellItem no.:
TC-K13/J13Payment:
T.T, Credit Card, Paypal etc, to be negotiateMarket price:
$20Price:
$15Product origin:
Made in ChinaColor:
Yellow (Type J)、 Green (Type K)Min order:
10 PCSProduct weight:
0.2kgLead Time:
14 days after payment confirmedKey Features:
Dual Types Available: Type K (Green, max 700°C) & Type J (Yellow, max 500°C).
Premium Construction: SS316 stainless steel sheath with mineral insulation for durability.
Standard Dimensions: 1/4" (6.35mm) diameter x 150mm probe length; 10mm x 40mm transition part.
Ready to Install: Includes a 2m silicone cable and a grounded junction (GD) configuration.
Interchangeable: Both types share the exact same physical dimensions; simply select the matching input on your instrument.
| Parameter |
Type K |
Type J |
|
Sensor type |
Type K thermocouple | Type J thermocouple |
|
Physical shape |
Identical to Type J | Identical to Type K |
|
Configuration |
Probe with transition part | Probe with transition part |
|
Probe diameter |
1/4 in(6.35 mm) | 1/4 in(6.35 mm) |
|
Probe length |
150 mm | 150 mm |
|
Transition / cold-junction part size |
10 mm x 40 mm | 10 mm x 40 mm |
| Probe material | SS316 stainless steel | SS316 stainless steel |
| Maximum allowable temperature |
700 °C* |
500 °C* |
| Cable | 2 m, green silicone | 2 m, green silicone |
| Wire specification | 2x7x0.2 | 2x7x0.2 |
| Probe construction | Mineral insulated | Mineral insulated |
TYPE K | GREEN CABLE
TC-K13-1/4-150-10-40-2000-SS-GD-700-SS316
700 °C maximum allowable temperature*
TYPE J | YELLOW CABLE
TC-J13-1/4-150-10-40-2000-SS-GD-500-SS316
500 °C maximum allowable temperature*
How to read the code
|
TC |
Means PIDMaxwell Thermocouple, short for TC |
|
K13/J13 |
Product code, K13 or J13 |
|
1/4 |
Probe diameter |
|
150 |
Probe length |
|
10-40 |
Diameter and length of the transition part |
|
2000 |
2 m cable length |
|
SS |
Stainless steel cable |
|
GD |
Grounded version |
|
500 |
Maximum allowable temperature is 500 degree celsius |
|
SS316 |
Probe is stainless steel 316 |
The standard configuration described by either code includes an SS316 mineral-insulated probe, a 10 mm × 40 mm transition / cold-junction part and wire specification 2 × 7 × 0.2. *Temperature unit assumed to be °C; confirm before use.
Installation & selection FAQs
Practical guidance for choosing and using these two configurations. Temperature values are shown in °C; the unit should be confirmed.
1. What is the difference between the two sensors?
Type K has a green cable and a specified maximum allowable temperature of 700 °C. Type J has a yellow cable and a specified maximum of 500 °C.
2. Are the probes physically interchangeable?
Their physical shape and stated dimensions are identical. Their thermocouple types differ, so the receiving instrument must be configured for the correct type.
3. Does the maximum temperature apply to the cable?
Do not assume so. The silicone cable, transition and termination ratings were not provided and may be lower than the sensor maximum. Verify the rating of each part before use.
4. What instrument can I use?
Use a thermocouple input that supports the selected Type K or Type J and provides suitable cold-junction compensation. Select the matching input type in the instrument settings.
5. How do I connect the leads?
Confirm positive and negative lead identification with the supplier or the sensor documentation, then connect them to the corresponding instrument terminals. Do not infer polarity from the outer cable color.
6. Can I extend the cable?
Use extension or compensating wire and connectors compatible with the selected thermocouple type, observing polarity. Confirm that the extension and connectors suit the installation temperatures.
7. Is the transition part the cold-junction compensation point?
Not necessarily. The 10 mm × 40 mm part is the supplied transition dimension. Cold-junction compensation is determined by the measurement circuit and its reference- junction location. [1]
8. Is the measuring junction grounded or ungrounded?
The junction construction was not specified. Confirm it with the supplier if electrical isolation or response characteristics are important to your application.
9. What accuracy and minimum temperature are guaranteed?
A tolerance class, calibration certificate and minimum temperature were not supplied. Confirm the required range and accuracy before ordering or relying on the measurement.
10. Can the sensor be used in moisture or corrosive media?
The probe material is SS316, but an ingress-protection rating and chemical compatibility were not specified. Evaluate the complete assembly and process conditions with the supplier.
11. Can other lengths or connectors be ordered?
The listed configuration has a 150 mm probe and a 2 m silicone cable. Alternative lengths, terminations and other options are not specified; ask the supplier about availability.
12. How should the probe be installed?
Mount the probe securely at the measurement point. Protect the cable and transition from excess heat and mechanical strain; confirm immersion requirements and component temperature limits.